City of Mobile

Home Status Parcel Help

View Case Status

The information below summarizes the case you selected.

Case Number:  BLD2015-00185      Status:   FIN
Name:  COMMERCIAL RENOVATORS INC
Application Date: 1/23/2015 2:21:23 PM
Address: 1390 TINGLE CIR W D-6

Activities
Type  Requested  Scheduled  Completed  Assigned To  Done By  Disp 
Plans/App. Received      01/23/2015    WMF  DONE 
Verify Contractor License  01/23/2015    02/26/2015    38  DONE 
(Add Initial Status Check!)          WMF  DONE 
LUD Plan Review   01/23/2015    01/29/2015    CW  DONE 
COM: NO PLANS 
LUD Approval  01/23/2015    01/29/2015    CW  DONE 
COM 
Traffic Approval   01/23/2015    01/23/2015    WMF  CANC 
Tree Review  01/23/2015    01/23/2015    WMF  CANC 
Engineering Plan Review  01/23/2015    01/23/2015    WMF  CANC 
Building Plan Review  01/23/2015    01/27/2015  JD  FAIL 
See Conditions, no resubmittal fee 
Plumbing Plan Review  01/23/2015    02/02/2015  JA  JA  FAIL 
NEEDS TO CORRECT THE FOLLOWING: 1-MAX HEIGHT ON THE LAVATORIES IS 34" TO COUNTER TOP OR LAV TOP, WHICH EVER IS HIGHER 2-BOTTOM FED WATER HEATER SHALL HAVE WATER SUPPLY AND VACUUM BREAKER ABOVE THE TOP OF THE HEATER BEFORE GOING DOWN TO CONNECTION (P.101) 3-NEED ISOMETRIC RISER DIAGRAM FOR DWV WITH PIPE SIZES 4-NEED PLUMBING FIXTURE SCHEDULE 5-NEED GREASE TRAP SIZING FORMULA AND MATH (FROM LOCAL ORDINANCE) TO BE SHOWN 6-PUBLIC HAND WASHING FACILITIES REQUIRE TEMPERED WATER BY A MIXING VALVE MEETING ASSE 1070 7-THE DRAIN FOR THE DRINK STATION AND SURROUNDING AREA, SHALL GO THROUGH THE GREASE TRAP 8-SAMPLING PORT, ONE SIZE LARGER THAN DISCHARGE PIPE, REQUIRED ON DISCHARGE SIDE OF GREASE TRAP / INTERCEPTOR COMMENTS OR CONCERNS: JOE ALEXANDER PLUMBING INSPECTOR I (251) 208-7606--OFFICE (251) 208-7023--FAX alexander@cityofmobile.org  
Mechanical Plan Review  01/23/2015    01/28/2015  12  AM  FAIL 
1. As per State of Alabama- need to provide Energy Code documentation- 2009 International Energy Conservation Code or Ashrae 90.1-2007. 2. Need to provide Fresh Air Calculations as per Ashrae 62.1 3. Note- Kitchen Exhaust hoods required to have Fire Suppression system. *Contact: Al McNab Chief Mechanical Inspector 251-208-7424 mcnaba@cityofmobile.org 
Electrical Plan Review  01/23/2015    01/29/2015  44  44  FAIL 
Need Energy Code compliance documentation. 
Fire Dept Plan Review  01/23/2015    01/30/2015    SLA  DONE 
Ok to permit - Provide locking Knox box upon completion of project. Office use only: Occupant load 119 sprinkled, fire alarm,  
Fax Plan Review Results!  01/23/2015    01/23/2015    WMF  CANC 
Flood Certificate on File?  01/23/2015    01/27/2015    LKC  N/A 
X-UNSHADED 
Lateral Number Entered  01/23/2015    05/19/2015    38  DONE 
12016 
Land Disturbance Issued?  01/23/2015    02/26/2015    LKC  DONE 
ROW Approval (prior to C/O)   01/23/2015           
Tracking Info Sheet Sent      01/27/2015    LKC  DONE 
FAXED 
Initial Status Check       01/23/2015    WMF  DONE 
Revised PLM Plans Rec'd  02/25/2015    02/26/2015  JA  JA  DONE 
OK 
Revised MEC Plans Rec'd  02/25/2015    02/25/2015  12  AM  DONE 
Revised ELE Plans Rec'd  02/25/2015    02/26/2015  44  44  DONE 
1st Revised BLD Plans Rec'd  02/25/2015    02/26/2015  21  21  DONE 
ok condition met. made minor changes on sheets 100-101-131-501 
Permit is Ready to Issue!!  02/26/2015    02/26/2015    LKC  DONE 
READY TO ISSUE: plans, app, card & job folder beside filing cabinet outside MDS' office. Spreadsheet complete thru 2/26/15. 
Issue Permit      02/27/2015    38  DONE 
Revised PLM Plans Rec'd  03/02/2015    03/03/2015  16  16  DONE 
Revised grease trap sizing formula and letter from owner stating paper products only. 
Slab Inspection  03/09/2015    03/10/2015  19  RTM  DONE 
702-513-7394 am inspection 3/10/15 Ok for D-6 and D-5. 
Framing Inspection  03/12/2015    03/13/2015  21  21  FAIL 
LATE PM POSSIBLY LAST OF THE DAY 702-513-7394. Not ready needs building dried in 
ALL MEP FEES PAID      03/19/2015    LD  DONE 
Framing Re-Inspection  04/01/2015    04/03/2015  21  21  PTL 
PM 251-689-7448 Demizeing wall only 
Framing Inspection  04/06/2015    04/08/2015  19  RTM  DONE 
am 251-689-7448 All walls ok. 
Initial Status Check       04/29/2015    38  DONE 
Partial Framing Inspection  05/18/2015    05/18/2015  21  21  DONE 
PM-(AFTER LUNCH/OVERHEAD/NEW D-6/DICKEYS BBQ) 
Final Inspection-ZON  05/27/2015    05/28/2015    JDS  TEMP 
Visited site on 5/28/15. OK for temp. 
Final Approval-ZON  05/27/2015    05/28/2015    BH  TEMP 
Temp CO. Still need as builts for overall site. 
Initial Status Check       05/27/2015    38  DONE 
Override - Activity Holds      05/27/2015    38   
Special Inspections Report      05/28/2015  JD  DONE 
NA 
Fin. Insp-Bldg-Add C/O Reqst   05/27/2015    05/28/2015  21  21  DONE 
AM -- 251-581-4932 
Final Inspection-ENG  05/28/2015    05/28/2015    RGS  TEMP 
TEMP ONLY - ok with revised conditions.  
Final Inspection-ROW  05/28/2015    05/28/2015    RGS  TEMP 
TEMP ONLY ok with revised conditions 
Final Inspection-FIR  05/29/2015    05/29/2015    MSC  DONE 
LETTER OF SUBSTANTIAL COMP.      05/29/2015  19  RTM  DONE 
L/S/C FROM MARION ANTHONY HARDY ARCH#6568 ATTACHED Ok. 
Issue Temp Cert of Occupancy  05/29/2015        38  DONE 
EXPIRES: 6/28/15 
Final Re-Inspection-ZON  07/31/2015    07/31/2015    JDS  TEMP 
Site visited on 7/30/15. OK for Temp CO. 
Final Approval-ZON  07/31/2015    07/31/2015    BH  TEMP 
Temp CO 
Final Re-Inspection-ZON  09/15/2015    09/15/2015    BH  DONE 
All replacement trees to be in ground by Dec 31, 2015. BH FOR PERMANENT C/O BASED ON AS-BUILT DWGS REC'D 9/2/15 
Final Approval-ZON  09/15/2015    09/15/2015    BH  DONE 
All replacement trees to be in ground by Dec 31, 2015. BH 
Issue Final Cert of Occupancy      09/30/2015    38  DONE 
CO#8634 9/15/15 
Case Finaled      09/30/2015    38  DONE 

Conditions
Title Id Tag Status
Misc. Hold With Overide 0150:1    Met
RETURN SPEC BOOK TO CUSTOMER AFTER DURING ISSURANCE-WMF- 1/23/2015 
ACCESSIBILITY 0150:1    Met
Accessibility Handi-Cap Design: Buildings and facilities shall be designed and constructed to be accessible in accordance with the 2009 IBC and ICC/ANSI A117.1 Note:ANSI A117.1, Section 604.5.1 sidewall grab bar 18 inch  

Fees   
Item  Fee Amount  Fee Remaining 
Permit Fee  1,074.15  0.00 
Plan Review Fee Commercial  100.00  0.00 
Plan Review Fee Commercial  100.00  0.00 
TEMPORARY C/O  100.00  0.00 
TEMPORARY C/O  100.00  0.00 
TEMPORARY C/O  100.00  0.00 
FIRE PLAN REVIEW (SMALL)  85.00  0.00 
FIRE PROCESS FEE  1.00  0.00 
COMPUTER/FAX FEE  1.00  0.00 
COMPUTER/FAX FEE ELECTRICAL  1.00  0.00 
COMPUTER/FAX FEE MECHANICAL  1.00  0.00 
COMPUTER/FAX FEE PLUMBING  1.00  0.00 
COMPUTER/FAX FEE  1.00  0.00 
COMPUTER/FAX FEE  1.00  0.00 
COMPUTER/FAX FEE  1.00  0.00 
COMPUTER/FAX FEE  1.00  0.00 
COMPUTER/FAX FEE  1.00  0.00 

 


What would you like to do next?

Back to Search
Help Top of Page